| Sr. No. | Specifications | Chemistry |
|---|---|---|
| 1 | 3.7V 2Ah | NMC |
| 2 | 3.7V 2.2Ah | NMC |
| 3 | 3.7V 4.4Ah | NMC |
| 4 | 7.4V 2.2Ah | NMC |
| 5 | 7.4V 4.4Ah | NMC |
| 6 | 7.4V 4.4Ah | NMC |
| 7 | 11.1V 2.2Ah | NMC |
| 8 | 11.1V 2.5Ah | NMC |
| 9 | 11.1V 5Ah | NMC |
| 10 | 11.1V 7.5Ah | NMC |
| 11 | 14.8V 2.2Ah | NMC |
| 12 | 14.8V 2.5Ah | NMC |
| 13 | 14.8V 5Ah | NMC |
From a pocket torch to a street light, our NMC cells and packs give lighting products steady brightness, long runtime and quick recharging in a small body.
Switches on instantly during a power cut and holds charge while it waits in standby.
Light, rechargeable and easy to carry for home, travel and camping use.
Stores daytime solar energy and powers LEDs through the night.
Cordless lighting for workshops, repair jobs and field work, with no wire to trip over.
| Pack Voltage | Cells in Series | Typical Use |
|---|---|---|
| 3.7 V | 1 | Torches, small LED lamps |
| 7.4 V | 2 | Emergency lights, lanterns |
| 11.1 V | 3 | Rechargeable bulbs, work lights |
| 14.8 V | 4 | High-power LED and outdoor lights |
Each cell is 3.7 V. Joining more cells in series raises the pack voltage. Higher Ah gives longer runtime.
Two numbers decide runtime: how much energy the pack stores and how much power your light uses.
Energy (Wh) = Voltage (V) × Capacity (Ah)
Runtime (hours) ≈ Energy (Wh) ÷ Light power (W)
An 11.1 V, 5 Ah pack stores 11.1 × 5 = 55.5 Wh. A 10 W LED light drains it in about 55.5 ÷ 10 = 5.5 hours. Real runtime is slightly lower because of driver losses.
| Pack | Energy | Runs a 10 W Light For |
|---|---|---|
| 3.7 V 2 Ah | 7.4 Wh | about 45 minutes |
| 7.4 V 2.2 Ah | 16.3 Wh | about 1.6 hours |
| 7.4 V 4.4 Ah | 32.6 Wh | about 3.3 hours |
| 11.1 V 5 Ah | 55.5 Wh | about 5.5 hours |
| 11.1 V 7.5 Ah | 83.3 Wh | about 8.3 hours |
| 14.8 V 5 Ah | 74 Wh | about 7.4 hours |
Approximate figures. Actual runtime depends on your light's real power draw.
A battery management circuit watches the pack so your lighting product stays safe in daily use.
Stops charging when the pack is full, so the cells are not stressed.
Cuts off the load before the battery drains too low and gets damaged.
Disconnects the output quickly if a wiring fault shorts the terminals.
In multi-cell packs, keeps cells at similar levels for even wear.
Protection features vary by pack. Ask us to confirm what is included in the model you need.
Yes. Share the voltage, capacity, size limit and connector type you need, and we will suggest a pack built around them.
Match the input voltage your LED driver expects. Then pick the Ah based on how many hours of light you need, using the runtime guide above.
Use a lithium-ion charger rated for the pack's voltage. A 3-cell 11.1 V pack, for example, needs a charger made for 3-cell lithium-ion, not a lead-acid charger.
Yes, if the solar controller supports lithium-ion charging at the pack voltage. Tell us your controller model and we will confirm.
Yes. Send your monthly quantity and specifications and we will share availability and terms.
Tell us your voltage, capacity and size needs. We will recommend a cell or build a custom pack.